A galvanometer of resistance $100\ \Omega$ has 50 divisions on its scale and has sensitivity of $20\mu\mathrm{A}\ /\ \mathrm{division}$ . It is to be converted to voltmeter with three ranges, of $0 - 2\ \mathrm{V}, 0 - 10\ \mathrm{V}$ and $0 - 20\ \mathrm{V}$. The appropriate circuit to do so is:

- (1)
see figure G followed in series by $\mathrm{R_1 = 19900\ \Omega}$, $\mathrm{R_2 = 9900\ \Omega}$, $\mathrm{R_3 = 1900\ \Omega}$, with terminals tapped from the junctions labelled, from left to right, 20 V, 10 V, 2 V
- (2)
see figure G followed in series by $\mathrm{R_1 = 1900\ \Omega}$, $\mathrm{R_2 = 9900\ \Omega}$, $\mathrm{R_3 = 19900\ \Omega}$, with terminals labelled, from left to right, 2 V, 10 V, 20 V
- (3)
see figure G followed in series by $\mathrm{R_1 = 2000\ \Omega}$, $\mathrm{R_2 = 8000\ \Omega}$, $\mathrm{R_3 = 10000\ \Omega}$, with terminals labelled, from left to right, 2 V, 10 V, 20 V
- (4)
see figure G followed in series by $\mathrm{R_1 = 1900\ \Omega}$, $\mathrm{R_2 = 8000\ \Omega}$, $\mathrm{R_3 = 10000\ \Omega}$, with terminals labelled, from left to right, 2 V, 10 V, 20 V
Show answer
Option (4) is correct.
Key from source paper